1.
Anal Chim Acta ; 1291: 342219, 2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38280790

RESUMO

The detection of intrinsic protein fluorescence is a powerful tool for studying proteins in their native state. Thanks to its label-free and stain-free feature, intrinsic fluorescence detection has been introduced to polyacrylamide gel electrophoresis (PAGE), a fundamental and ubiquitous protein analysis technique, to avoid the tedious detection process. However, the reported methods of intrinsic fluorescence detection were incompatible with online PAGE detection or standard slab gel. Here, we fulfilled online intrinsic fluorescence imaging (IFI) of the standard slab gel to develop a PAGE-IFI method for real-time and quantitative protein detection. To do so, we comprehensively investigated the arrangement of the deep-UV light source to obtain a large imaging area compatible with the standard slab gel, and then designed a semi-open gel electrophoresis apparatus (GEA) to scaffold the gel for the online UV irradiation and IFI with low background noise. Thus, we achieved real-time monitoring of the protein migration, which enabled us to determine the optimal endpoint of PAGE run to improve the sensitivity of IFI. Moreover, online IFI circumvented the broadening of protein bands to enhance the separation resolution. Because of the low background noise and the optimized endpoint, we showcased the quantitative detection of bovine serum albumin (BSA) with a limit of detection (LOD) of 20 ng. The standard slab gel provided a high sample loading volume that allowed us to attain a wide linear range of 0.03-10 µg. These results indicate that the PAGE-IFI method can be a promising alternative to conventional PAGE and can be widely used in molecular biology labs.


Assuntos
Imagem Óptica , Soroalbumina Bovina , Eletroforese em Gel de Poliacrilamida
2.
Clin Chim Acta ; 552: 117685, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38030031

RESUMO

Hemoglobin (Hb) abnormalities, such as thalassemia and structural Hb variants, are among the most prevalent inherited diseases and are associated with significant mortality and morbidity worldwide. However, there were not comprehensive reviews focusing on different clinical analytical techniques, research methods and artificial intelligence (AI) used in clinical screening and research on hemoglobinopathies. Hence the review offers a comprehensive summary of recent advancements and breakthroughs in the detection of aberrant Hbs, research methods and AI uses as well as the present restrictions anddifficulties in hemoglobinopathies. Recent advances in cation exchange high performance liquid chromatography (HPLC), capillary zone electrophoresis (CZE), isoelectric focusing (IEF), flow cytometry, mass spectrometry (MS) and polymerase chain reaction (PCR) etc have allowed for the definitive detection by using advanced AIand portable point of care tests (POCT) integrating with smartphone microscopic classification, machine learning (ML) model, complete blood counts (CBC), imaging-based method, speedy immunoassay, and electrochemical-, microfluidic- and sensing-related platforms. In addition, to confirm and validate unidentified and novel Hbs, highly specialized genetic based techniques like PCR, reverse transcribed (RT)-PCR, DNA microarray, sequencing of genomic DNA, and sequencing of RT-PCR amplified globin cDNA of the gene of interest have been used. Hence, adequate utilization and improvement of available diagnostic and screening technologies are important for the control and management of hemoglobinopathies.


Assuntos
Hemoglobinopatias , Hemoglobinas Anormais , Talassemia , Humanos , Hemoglobinas Anormais/genética , Hemoglobinas Anormais/análise , Inteligência Artificial , Hemoglobinopatias/diagnóstico , Hemoglobinopatias/genética , Hemoglobinas/análise , Focalização Isoelétrica , Cromatografia Líquida de Alta Pressão
3.
J Chromatogr A ; 1713: 464571, 2024 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-38091846

RESUMO

Polyacrylamide gel electrophoresis (PAGE) is one of the most popular techniques for the separation and detection of nucleic acids. However, it requires a complicated detection procedure and offline detection format, which inevitably leads to band broadening and thus compromises the separation resolution. To overcome this problem, we developed an online PAGE (OPAGE) platform by integrating the gel electrophoresis apparatus with the gel imaging system, so as to obviate the need for the complicated detection procedure. Notably, OPAGE enabled the real-time monitoring of the separation process and the immediate imaging of the separation results once the electrophoresis ended. Using a series of synthetic DNAs with different lengths as samples, we demonstrated that the OPAGE platform enhanced 32-64 % of the number of theoretical plates, showed a robust dynamic range of 0.1-12.5 ng/µL, and realized a limit of detection as low as 0.08 ng/µL DNA. Based on our results, we anticipate that the OPAGE platform is a promising alternative to traditional nucleic acid gel electrophoresis for simple and high-resolution detection and quantification and nucleic acid.


Assuntos
DNA , Ácidos Nucleicos , Eletroforese em Gel de Poliacrilamida
4.
Anal Chem ; 95(37): 13941-13948, 2023 09 19.
Artigo em Inglês | MEDLINE | ID: mdl-37653711

RESUMO

Isoelectric focusing (IEF) is a powerful tool for resolving complex protein samples, which generates IEF patterns consisting of multiplex analyte bands. However, the interpretation of IEF patterns requires the careful selection of isoelectric point (pI) markers for profiling the pH gradient and a trivial process of pI labeling, resulting in low IEF efficiency. Here, we for the first time proposed a marker-free IEF method for the efficient and accurate classification of IEF patterns by using a convolutional neural network (CNN) model. To verify our method, we identified 21 meat samples whose IEF patterns comprised different bands of meat hemoglobin, myoglobin, and their oxygen-binding variants but no pI marker. Thanks to the high throughput and short assay time of the microstrip IEF, we efficiently collected 1449 IEF patterns to construct the data set for model training. Despite the absence of pI markers, we experimentally introduced the severe pH gradient drift into 189 IEF patterns in the data set, thereby omitting the need for profiling the pH gradient. To enhance the model robustness, we further employed data augmentation during the model training to mimic pH gradient drift. With the advantages of simple preprocessing, a rapid inference of 50 ms, and a high accuracy of 97.1%, the CNN model outperformed the traditional algorithm for simultaneously identifying meat species and cuts of meat of 105 IEF patterns, suggesting its great potential of being combined with microstrip IEF for large-scale IEF analyses of complicated protein samples.


Assuntos
Aprendizado Profundo , Focalização Isoelétrica , Ponto Isoelétrico , Algoritmos , Carne
5.
Biosens Bioelectron ; 237: 115482, 2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37406479

RESUMO

Desalting of biosamples is crucial for analytical techniques intolerant to abundant salts. However, there is no simple tool to monitor the desalting of low-volume biosamples so far. Here we developed a handheld capacitively coupled contactless conductivity detector (hC4D) as a miniaturized device to measure the conductivity of 75 µL biosamples. Polyether-ether-ketone (PEEK) tubing was selected as the sample reservoir for sample loading via a pipette. Another pipetting of air pushed the sample solution out of the tubing to recollect the sample. Owing to the low sample consumption and easy sample recollection, hC4D is advantageous for testing expensive biosamples, such as viruses and cells. In addition, the whole process of sample injection, conductivity measurement, recollection, and calibration of conductivity can be completed within 1 min. To verify the feasibility of hC4D, we monitored the desalting progress of gel filtration (GF) of 200 µL blood samples, ultrafiltration (UF) of 300 µL virus samples, and dialysis of 7 mL cell samples. Three rounds of GF and UF completely removed the salts but led to poor sample recovery. In contrast, low concentrations of residual salts remained and better recovery was achieved after two rounds of GF and UF. We further utilized the hC4D to monitor the dialysis and tuned the salt concentration in the cell sample, such that we maintained the viability of cells in a low conductivity environment. These results indicated that hC4D is a promising tool for optimizing the desalting procedure of low-volume biosamples.


Assuntos
Técnicas Biossensoriais , Eletroforese Capilar , Eletroforese Capilar/métodos , Sais , Cetonas , Polietilenoglicóis , Condutividade Elétrica
6.
Anal Methods ; 15(24): 2971-2978, 2023 06 22.
Artigo em Inglês | MEDLINE | ID: mdl-37309647

RESUMO

Cholesterol (CHO) in human blood is one of the most frequently and crucially quantified substances in diagnostic laboratories. However, visual and portable point of care testing (POCT) methods have been rarely developed for the bioassay of CHO in blood samples. Here, we developed an electrophoresis titration (ET) model, a chip device of ∼60 grams, and a quantification method for the POCT of CHO in blood serum based on a moving reaction boundary (MRB). In this model, the selective enzymatic reaction is integrated with an ET chip for visual and portable quantification. At first, CHO reacted with cholesterol oxidase (CHOx) in the anode well, producing H2O2 and cholest-4-en-3-one in the solution. H2O2 further oxidized the colorless and chargeless leucocrystal violet (LCV) dye into violet colored positively charged crystal violet (CV+) and, under the influence of the electric field, the CV+ migrates in the ET channels and is titrated by the alkali of sodium hydroxide immobilized in the ET channels. The length covered by the MRB was measured as a function of the CHO content. The relevant experiments validated the feasibility of the model and method. Furthermore, the experiments revealed the high selectivity, portability, and visuality of the ET-MRB model, device, and method. Finally, the experiments showed a fair sensitivity of LOD of 5 µM, good linearity of 10-1000 µM (r2 = 0.9919), fair stability (intra-day RSD of less than 5.09% and an inter-day RSD of less than 6.36%), and high recovery (99.4-105%). All the data and results indicate the potential of the ET-MRB model, chip device, and method for POCT of CHO in human blood samples.


Assuntos
Peróxido de Hidrogênio , Soro , Humanos , Peróxido de Hidrogênio/química , Eletroforese/métodos , Colesterol Oxidase , Testes Imediatos
7.
Food Res Int ; 166: 112600, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36914325

RESUMO

In this work, by combining the microcolumn isoelectric focusing (mIEF) and similarity analysis with the earth mover's distance (EMD) metric, we proposed the concept of isoelectric point (pI) barcode for the identification of species origin of raw meat. At first, we used the mIEF to analyze 14 meat species, including 8 species of livestock and 6 species of poultry, to generate 140 electropherograms of myoglobin/hemoglobin (Mb/Hb) markers. Secondly, we binarized the electropherograms and converted them into the pI barcodes that only showed the major Mb/Hb bands for the EMD analysis. Thirdly, we efficiently developed the barcode database of 14 meat species and successfully used the EMD method to identify 9 meat products thanks to the high throughput of mIEF and the simplified format of the barcode for similarity analysis. The developed method had the merits of facility, rapidity and low cost. The developed concept and method had evident potential to the facile identification of meat species.


Assuntos
Algoritmos , Hemoglobinas , Ponto Isoelétrico , Carne/análise
8.
Clin Chim Acta ; 538: 124-130, 2023 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-36400321

RESUMO

Traditional capillary isoelectric focusing (cIEF), liquid chromatography (LC) and capillary zone electrophoresis (CZE) still suffered from low resolution for hemoglobinopathy screening. Herein, a 30-mm pH 5.2-7.8 microcolumn IEF (mIEF) array chip was developed for hemoglobinopathy screening. As a proof of concept, adult beta-thalassemia was chosen as a model disease. In the method, blood samples were hemolyzed via hemolysin solution and loaded into the microcolumn. The experiments showed that (i) the species of Hb A, F, A2 and variants were clearly separated in the chip, and the resolution was greatly higher than the ones of LC/CZE/cIEF; (ii) up to 24 samples could be simultaneously analyzed in 12-min run; (iii) the intraday and interday RSDs were respectively 3.32-4.91 % and 4.07-5.33 %. The assays of mIEF to total 634 samples were compared with the ones of LC (n = 327) and PCR (n = 307). The cutoff of 3.5 % HbA2 led to the sensitivity of 100 % and specificity of 89.1 % for the mIEF-based screening; and there was 96.7 % coincidence between the methods of mIEF and PCR if refer Hb A2 and F. The method had the merits of facility, efficiency, specificity and sensitivity in contrast to the currently-used methods, implying its potential to screening of beta-thalassemia and hemoglobinopathies.


Assuntos
Hemoglobinopatias , Talassemia , Talassemia beta , Humanos , Adulto , Talassemia beta/diagnóstico , Hemoglobinopatias/diagnóstico , Focalização Isoelétrica/métodos , Cromatografia Líquida
9.
J Chromatogr A ; 1663: 462747, 2022 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-34973480

RESUMO

Free-flow isoelectric focusing (FFIEF) is a useful tool for separating and purifying proteins, DNA, cells, and organelles, etc. However, the online monitoring of each fraction during an FFIEF run has not been achieved yet, resulting in a lack of process monitoring of FFIEF. Herein, an online array ultraviolet (UV) detection system was developed for the easy assay of FFE fractions. The detector was integrated with an apparatus of FFIEF with 32 fractions to show the online monitoring, and bovine serum albumin (BSA) and lysozyme were chosen as the model proteins for manifesting the UV detector performance. The experiments revealed that (i) all the fluidic cells had good linearity from 0.03 to 10 mg/mL BSA and fair limits of detection (LODs) of 0.01 mg/mL; (ii) all the cells had good uniformity of UV absorbance; and (iii) the deviations of intra-day and inter-day of UV detector were respectively 3.8% and 5.8%, indicating the fair stability of the UV detector. The UV detector could be well used for the process monitoring of two model proteins through the whole FFIEF run, and the online absorbance assay of proteins at the end of FFIEF. The UV detector herein had the evident potential for rapid and convenient assay of protein fraction in FFIEF as well as other FFE modes.


Assuntos
Soroalbumina Bovina , Focalização Isoelétrica
10.
Anal Chem ; 94(4): 2007-2015, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-34958211

RESUMO

Gel electrophoresis (GE) is one of the most general tools in biomedicine. However, it suffers from low resolution, and its mechanism has not been fully revealed yet. Herein, we presented the dispersion model of w2 (t) ∝ Tt, showing the band dispersion (w) via temperature (T) and running time (t) control. Second, we designed an efficient GE chip via the time control and rapid Joule heat self-dissipation by thermal conductive plastic (TCP) and electrode buffer. Third, we conducted the simulations on TCP and polymethylmethacrylate (PMMA) chips, unveiling that (i) the temperature of TCP was lower than the PMMA one, (ii) the temperature uniformity of TCP was better than the PMMA one, and (iii) the resolution of TCP was superior to the PMMA one. Fourth, we designed both TCP and PMMA chips for experimentally validating the dispersion model, TCP chip, and simulations. Finally, we applied the TCP chip to thalassemia and model urine protein assays. The TCP chip has merits of high resolution, rapid run of 6-10 min, and low cost. This work paves the way for greatly improving electrophoretic techniques in gel, chip, and capillary via temperature and time control for biologic study, biopharma quality control, clinical diagnosis, and so on.


Assuntos
Temperatura Alta , Corrida , Eletroforese , Polimetil Metacrilato , Temperatura
11.
Electrophoresis ; 41(16-17): 1529-1538, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32529672

RESUMO

As an effective separation tool, free-flow electrophoresis has not been used for purification of low-abundance protein in complex sample matrix. Herein, lysozyme in complex egg white matrix was chosen as the model protein for demonstrating the purification of low-content peptide via an FFE coupled with gel fitration chromatography (GFC). The crude lysozyme in egg while was first separated via free-flow zone electrophoresis (FFZE). After that, the fractions with lysozyme activity were condensed via lyophilization. Thereafter, the condensed fractions were further purified via a GFC of Sephadex G50. In all of the experiments, a special poly(acrylamide- co-acrylic acid) (P(AM-co-AA)) gel electrophoresis and a mass spectrometry were used for identification of lysozyme. The conditions of FFZE were optimized as follows: 130 µL/min sample flow rate, 4.9 mL/min background buffer of 20 mM pH 5.5 Tris-Acetic acid, 350 V, and 14 °C as well as 2 mg/mL protein content of crude sample. It was found that the purified lysozyme had the purity of 80% and high activity as compared with its crude sample with only 1.4% content and undetectable activity. The recoveries in the first and second separative steps were 65% and 82%, respectively, and the total recovery was about 53.3%. The reasons of low recovery might be induced by diffusion of lysozyme out off P(AM-co-AA) gel and co-removing of high-abundance egg ovalbumin. All these results indicated FFE could be used as alternative tool for purification of target solute with low abundance.


Assuntos
Cromatografia em Gel/métodos , Clara de Ovo/química , Eletroforese/métodos , Muramidase/isolamento & purificação , Animais , Antibacterianos/análise , Antibacterianos/química , Antibacterianos/isolamento & purificação , Antibacterianos/farmacologia , Galinhas , Escherichia coli/efeitos dos fármacos , Testes de Sensibilidade Microbiana , Muramidase/análise , Muramidase/química , Muramidase/farmacologia